SUMMARY: Change failed disk RM6 & SDS

From: Luisa Jorge <luisa.jorge_at_nexinet.pt>
Date: Thu Aug 29 2002 - 11:47:35 EDT
Hello,
After all, the solution wasn4t difficult...
I made metadettach -f  in SDS on the parts of the mirror affected by the
disk (because in RM6 when I tried to run fix in recovery guru i got a
message that nobody could be accessing to the disk at that time), and when I
changed the disk, the LUN stayed in Optimal state.
After that, I4ve made metattach again... Right now one of the affected
partions is already mirrored... the other one still doing the resync...

Thanks to Diana Cabarello.

Regards,
Luisa.


----- Original Message -----
From: "Luisa Jorge" <luisa.jorge@nexinet.pt>
To: <sunmanagers@sunmanagers.org>
Sent: Wednesday, August 28, 2002 7:40 PM
Subject: UPDATE: Change failed disk RM6 & SDS


> Hello again...
>
>  I forgot to say that I have mirror between LUN4s but each LUN as a RAID 0
>  configuration.
>  I have been reading documents and they say that i have to reconstruct the
>  LUN again...
>  As anyone done this? should I do metadettach in SDS before reconstruct
the
>  LUN?
>  What is the correct procedure?
>
>   I will summarize...
>
>   Regards,
>   Luisa.
>
>
>  ----- Original Message -----
>  From: "Luisa Jorge" <luisa.jorge@nexinet.pt>
>  To: <sunmanagers@sunmanagers.org>
>  Sent: Tuesday, August 27, 2002 1:39 PM
> Subject: Change failed disk RM6 & SDS
>
> >
> > > Hello,
> > >
> > > I have this question:
> > >
> > > I have an E450 running solaris 2.6, whith two A1000 (with Raid 1)
> mirrored
> > > (using RM 6.22) - two LUNs, one per array. In SDS  I got a message
that
> > two
> > > of my partitions need maintenance. RM6 says that I have a disk failure
> in
> > > one of the LUNs. What is the correct procedure to change that disk...
> With
> > > SDS I know that I have to run metareplace... but what should I do with
> > Raid
> > > Manager? Should I destroy the failed LUN and build a new one? Or just
> > change
> > > the failed disk and run recovery guru? Doing the hot replacement
doesn4t
> > > need the disk format?
> > >
> > > I will summarize...
> > >
> > > Regards,
> > > Luisa.
> > > _______________________________________________
> > > sunmanagers mailing list
> > > sunmanagers@sunmanagers.org
> > > http://www.sunmanagers.org/mailman/listinfo/sunmanagers
> _______________________________________________
> sunmanagers mailing list
> sunmanagers@sunmanagers.org
> http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers