[SUMMARY: E4500 trouble

From: Dirk Boenning <dirk.boenning_at_ccf.de>
Date: Tue Mar 30 2004 - 09:13:42 EST
Hello,

again as fast as possible.
The winner is:

Alex Madden <Alex.Madden@betfair.com>

--
read about the obp command copy-clock-tod-to-io-boards
--

Dirk Boenning wrote:
> Hello,
> 
> 
> I've just tried to boot up an old E4500 after a couple of weeks powered 
> off and got the following message:
> 
> clockboard TOD does not match tod on any io board
> 
> The system doesn't boot but comes up to the OK prompt. It seems that the 
> I/O Boards not activated and the maintenace led on the clockboard is on.
> 
> Any glue what's going on and how to get this on up again ?
> 
> 
> TIA, Dirk.
> 
> 



-- 
CCF AG
Dirk Boenning
Daimlerstrasse 10
D-64347 Griesheim

t. +49 (0)6155/6668-0
f. +49 (0)6155/6668-68
e. dirk.boenning@ccf.de
w. www.ccf.de
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Tue Mar 30 09:23:01 2004