Hi, Thanks to all who replied especially Tony Walsh Anjan Dave Pascal >From whom I got the hint what to check for. Finally I figured it out. The problem was Active termination Jumper on the Diff controller card (SYMBIOS LOGIC - SYM 22802) was on (enabled). Disabled (Off) it and it started working. Thanks a lot and sorry if I missed anyone. Bhavesh My Original Question was: -------------------------- Hi Gurus, I have Sun Fire 280R Box where I have connected A1000 with PCI Diff SCSI Controller in slot PCI2 and am getting following error messages while booting: And sits there forever. WARNING: /pci@8,700000/scsi@3,1 (glm3): Connected command timeout for Target 3.0 WARNING: /pci@8,700000/scsi@3,1 (glm3): Target 3 reducing sync. transfer rate WARNING: /pci@8,700000/scsi@3,1 (glm3): got SCSI bus reset WARNING: /pci@8,700000/scsi@3,1 (glm3): Connected command timeout for Target 3.0 WARNING: /pci@8,700000/scsi@3,1 (glm3): got SCSI bus reset The same A1000 I connect to E 3500 works fine where we have S-BUS Diff SCSI controller. The PCI Diff SCSI controller is new. Any Help will be greatly appreciated. Thanks B _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagers _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Fri May 28 15:50:01 2004
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:31 EST