In short: *) X6729A is not supported on V880, use X6799A instead; *) To connect X6799A HBA to the switch, use an SC-LC cable; *) To connect a T3+ to the switch, use an LC-LC cable; *) Use an SFP to connect the "LC-end" of the cable to the switch; Million thanks to Drew Skinner, David Livingston and E. (NO UCE) for the following: Drew Skinner pointed out that the master of a T3+ partner pair would shut down both arrays if you fail to replace a FRU (a disk) within a certain time frame, and that in his opinion it's better if the T3+s are mirrored using SDS or similar software. David Livingston pointed out that I will need SC-LC cables to connect the HBAs to the switches, LC-LC cables to connect the T3+s to the switches, and SFP (370-5211) modules to connect the LC-end of the cables to the switches. E. (quote) "throwed a spanner in the works" by pointing out that X6729A isn't supported on USIII or higher CPU systems (this includes V880). Actually, this saved me a lot of grief, thanks, E!. Also, confirmed what cables I need. A great list, this is! Regards, Stoyan Genov Stoyan Genov wrote: > Good day, > > I have to set a pair of Sun Fire V880 machines, a pair of T3+ storage > arrays and a pair of SG-XSW8-2GB FC switches in the following way > (the idea of the setup being high availability of the data on the T3+s): > > [V880]---[fc switch]---[T3+] > | | | > +--------------+ | > | | | > +---------+ | | > | | | > [V880]---[fc switch]---[T3+] > > (ASCII art, please use a fixed width font to see drawing correctly) > > Each V880 has a pair of X6729A FC HBAs, and each of the X7629A's > connects to a port of a SG-XSW8-2GB switch. > > Each T3+ connects to a port of a switch (each array to different switch) > > The two T3+s are interconnected in a partner group. > > I need to obtain cables for all connections. > The question is, what exactly types of cables do I need? > Here are some thoughts on the subject: > > 1. T3+ interconnect cable: no variations. Just one type: 530-2843 > > 2. In the specs of the switch(es) > (http://sunsolve.sun.com/handbook_pub/Devices/Fibre_Channel/FIBRE_2GB_FC_Switch_8.html) > > I see that all cables are either LC-LC or LC-SC, which makes me think > I need LC on the switch's side. However, notes 3 and 4 on the same page > bother me -- I do not know whether the switches are 370-5211 or 370-5212 > > 3. In the specs of the T3+ > (http://sunsolve.sun.com/handbook_pub/Devices/Fibre_Channel/FIBRE_T3_RAID_Ctlr.html#5710) > > I see all cables are LC-SC, and there's an SC coupler offered. > Does that mean that I have to use an LC-LC cable to connect a T3 to > a switch, or an LC-SC+coupler+SC-LC? Or I have completely messed up? > > 4. In the specs of the HBA > (http://sunsolve.sun.com/handbook_pub/Devices/Fibre_Channel/FIBRE_Single_FC_AL.html) > > I can see the connector is SC duplex; does that mean I have to use an > SC-LC cable to connect a HBA to a switch? > > > Any comments, ideas and answers on the setup and the cables > will be greatly appretiated. I will summarize. > > Best Regards, > Stoyan Genov > _______________________________________________ > sunmanagers mailing list > sunmanagers@sunmanagers.org > http://www.sunmanagers.org/mailman/listinfo/sunmanagers _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Mon Jan 31 08:44:44 2005
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:43 EST