SUMMARY: Storedge 3511 / sccli

From: Geoff Lane <zzassgl_at_buffy.sighup.org.uk>
Date: Sun Aug 28 2005 - 11:29:44 EDT
Pascal got it right straight away - memo to self... Even if Sun supply
drivers on CD with new hardware, check the Sun web site for updates BEFORE
installation :-)

-----------------------------------------------------------------------------

I can't help much on that issue since I have mainly been working with 3510FC
so far. But I could read that you installed sccli 1.2.6. This is an old
version and it is highly recommended to install the latest which is 2.0. You
can find it on Sun's website following download, then storage management and
finally "3000 product family". You may need to update the firmware on the
disk-arrays to have all functions be supported !? Hope others will provide
you with more information relative to your problem.

Regards,
/Pascal

-----------------------------------------------------------------------------

Geoff Lane wrote:

>I have two Storedge 3511s and a 3510 connected via fibre and a McData fibre
>switch to a Sun V440 running Solaris 5.9 (Generic_118558-09).  The setup
>works and I have a number of LUNs configured on the 3511s/3510 and available
>to the V440.
>
>I've just installed SUNWsccli (version 1.2.6) on the server and am having
>some problems. When I select the 3510 and use the "show disks" I can see the
>disks on the 3510...
>
># sccli
>Available devices:
> 
>  1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
>  2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
>  3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
> 
>Please enter selection: 2
>sccli> show disks
>Ch  Id      Size   Speed  LD     Status   IDs
>----------------------------------------------------------------------
> 2   0  136.73GB   200MB  ld0    ONLINE   SEAGATE ST314680FSUN146G0307
> 2   1  136.73GB   200MB  ld0    ONLINE   SEAGATE ST314680FSUN146G0307
>         [ and so on ]
> 2  42  136.73GB   200MB  ld2    ONLINE   SEAGATE ST314680FSUN146G0307
> 2  43  136.73GB   200MB  ld2    ONLINE   SEAGATE ST314680FSUN146G0307
>sccli> q
>
>When I select a 3511, and run the "show disks" command I can't see any
>disks...
>
># sccli
>Available devices:
> 
>  1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
>  2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
>  3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
> 
>Please enter selection: 1
>sccli> show disks
>sccli: retrieving disk information: error: sm_err_database_update
>sccli>
>
>I get similar errors for a number of other sccli commands directed to
>either of the 3511s.
>
>I can't find anything about this in SunSolve or Google.  Does anybody have
>any idea what is causing the errors?
>
>Thanks,
>
>  
>







On Sun, Aug 28, 2005 at 03:54:18PM +0100, Geoff Lane wrote:
> I have two Storedge 3511s and a 3510 connected via fibre and a McData fibre
> switch to a Sun V440 running Solaris 5.9 (Generic_118558-09).  The setup
> works and I have a number of LUNs configured on the 3511s/3510 and available
> to the V440.
> 
> I've just installed SUNWsccli (version 1.2.6) on the server and am having
> some problems. When I select the 3510 and use the "show disks" I can see the
> disks on the 3510...
> 
> # sccli
> Available devices:
>  
>   1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
>   2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
>   3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
>  
> Please enter selection: 2
> sccli> show disks
> Ch  Id      Size   Speed  LD     Status   IDs
> ----------------------------------------------------------------------
>  2   0  136.73GB   200MB  ld0    ONLINE   SEAGATE ST314680FSUN146G0307
>  2   1  136.73GB   200MB  ld0    ONLINE   SEAGATE ST314680FSUN146G0307
>          [ and so on ]
>  2  42  136.73GB   200MB  ld2    ONLINE   SEAGATE ST314680FSUN146G0307
>  2  43  136.73GB   200MB  ld2    ONLINE   SEAGATE ST314680FSUN146G0307
> sccli> q
> 
> When I select a 3511, and run the "show disks" command I can't see any
> disks...
> 
> # sccli
> Available devices:
>  
>   1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
>   2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
>   3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
>  
> Please enter selection: 1
> sccli> show disks
> sccli: retrieving disk information: error: sm_err_database_update
> sccli>
> 
> I get similar errors for a number of other sccli commands directed to
> either of the 3511s.
> 
> I can't find anything about this in SunSolve or Google.  Does anybody have
> any idea what is causing the errors?
> 
> Thanks,
> 
> -- 
> Geoff Lane
> God invented SCO to give people a company to hate more than Microsoft.
> _______________________________________________
> sunmanagers mailing list
> sunmanagers@sunmanagers.org
> http://www.sunmanagers.org/mailman/listinfo/sunmanagers

-- 
Geoff Lane, 12 Moorside Rd, Tottington, BURY, BL8 3HW, 01204-88-3193
Elwood: It's a 106 miles to Chicago. We've got a full tank of gas, and a
        half a pack of cigarettes. It's dark, and we're wearing sunglasses.
Jake:   Hit it!
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Sun Aug 28 11:30:25 2005

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:51 EST