Hello folks, I would like to thank Aaron Lineberger, Victor Harrison and others for pointing me to the right direction. When I had initially sent this mail, I had failed to specify exactly which HBA card I was using. Well, the card I had was a Qlogic 2100F/66 HBA San Card. Qlogic QLA2100F which doesn't support Fabric Mode...which is why this wasn't working. After a "very" exhaustive research, I've found that the T3 array always talks loop mode (which a switch can handle properly), but more importantly it's the HBA card which needs to talk Fabric Mode (or connect on the F_Port in order for proper switch Fabric zoning to work). However, the Qlogic 2100F Card in the Netra T1 cannot do Fabric Mode...only Loop mode which is why this is not working. However, the Qlogic 2100F Card in the Netra T1 cannot do Fabric Mode...only Loop mode which is why this is not working. After the switch firmware upgrade, I now can enable Quick Loop which should allow me to connect these two devices. But, sadly, I need a license key for Quick Loop. As this product is End-Of-Life...there is no key ;-) . The only keys installed on the switch are for Fabric mode So, the Solution (I chose #1, #2 is an alternative): 1) Replace the HBA card with one that does do Fabric mode via SAN...In my case a Qlogic 2200F PCI Card. Once I put this in...everything started working. The card cost me an extra $40 on ebay and it works like a charm.. dmesg: .... Feb 25 13:37:42 san qla2200: [ID 857577 kern.notice] QLogic qla2200 Fibre Channel Driver v4.13.01 Instance: 0 Firmware v2.2.6 Feb 25 13:37:50 san qla2200: [ID 169035 kern.info] qla2200(0): Fibre Channel Loop is Down (8013) Feb 25 13:37:51 san qla2200: [ID 567540 kern.info] qla2200(0): Fibre Channel Loop is Up (8014) Feb 25 13:37:51 san qla2200: [ID 364886 kern.info] qla2200-hba0-adapter-node-name="200000e08b0567b8"; Feb 25 13:37:51 san qla2200: [ID 358785 kern.info] qla2200-hba0-adapter-port-name="210000e08b0567b8"; Feb 25 13:37:51 san qla2200: [ID 332924 kern.info] qla2200-hba0-adapter-port-id="010100"; Feb 25 13:37:51 san qla2200: [ID 823690 kern.info] qla2200-hba0-SCSI-target-id-1-fibre-channel-node-name="50020f20000043d4"; Feb 25 13:37:51 san qla2200: [ID 817589 kern.info] qla2200-hba0-SCSI-target-id-1-fibre-channel-port-name="50020f23000043d4"; Feb 25 13:37:51 san qla2200: [ID 699766 kern.info] qla2200-hba0-SCSI-target-id-1-port-id="0100e8"; Feb 25 13:37:51 san qla2200: [ID 418604 kern.info] qla2200-hba0-SCSI-target-id-1-lun-0-enable; Feb 25 13:37:51 san pci_pci: [ID 370704 kern.info] PCI-device: scsi@f, qla22000 Feb 25 13:37:51 san genunix: [ID 936769 kern.info] qla22000 is /pci@1f,0/pci@1/pci@1/scsi@f .... ----------------------------------------------------------------------------- Host Name : san OS Type : SunOS:sun4u OS Version : 5.9 FO API Version : 1.4.9.0 qlfoapi.a SDM API Version : 3.07 ----------------------------------------------------------------------------- 0 - QLA/QCP/QSB22xx OS: 0 WWPN: 21-00-00-E0-8B-05-67-B8 SN: D74887 FW: 2.2.6 IP ----------------------------------------------------------------------------- Total QLogic HBA(s) : 1 ==== HBA General Information ===================== ----------------------------------------------------------------------------- Host Name : san HBA Number : 0 OS Instance : 0 HBA Model : QLA/QCP/QSB 22xx HBA Node Name : 20-00-00-E0-8B-05-67-B8 HBA Port Name : 21-00-00-E0-8B-05-67-B8 HBA Port ID : 01-01-00 Serial Number : D74887 Driver Version : 4.13.01 FCode Version : 0.0 Firmware Version : 2.2.6 IP Device Target Count : 1 Actual Connection Mode : Point to Point Actual Data Rate : 1 Gbps PortType (Topology) : FPort HBA Status : Online ==== HBA NVRAM Settings Information ============== ----------------------------------------------------------------------------- QLogic HBA 0 - QLA/QCP/QSB22xx OS: 0 WWPN: 21-00-00-E0-8B-05-67-B8 ----------------------------------------------------------------------------- Connection Options : 2 - Loop Preferred, Otherwise Point-to-Point Frame Size : 1024 Hard Loop ID : 0 Loop Reset Delay (seconds) : 5 Enable Hard Loop ID : Disabled Enable FC Tape Support : Enabled Execution Throttle : 16 Enable Extended Error Logging: Disabled Login Retry Count : 8 Enable LIP Reset : Disabled Port Down Retry Count : 8 Enable LIP Full Login : Enabled Link Down Timeout (seconds) : 60 Enable Target Reset : Disabled LUNs Per Target : 8 Link Down Error : Enabled Fast Error Reporting : Disabled ==== Attached Devices/LUNs Information =========== ----------------------------------------------------------------------------- QLogic HBA 0 - QLA/QCP/QSB22xx OS: 0 WWPN: 21-00-00-E0-8B-05-67-B8 ----------------------------------------------------------------------------- Path : 0 Target : 1 Device ID : 0x01 Port ID : 01-00-E8 Product Vendor : SUN Product ID : T300 Product Revision : 0118 Node Name : 50-02-0F-20-00-00-43-D4 Port Name : 50-02-0F-23-00-00-43-D4 Product Type : Disk Number of LUN(s) : 1 Status : Online ----------------------------------------------------------------------------- Product Vendor : SUN Product ID : T300 Product Revision : 0118 LUN : 0 Size : 303.50 GB WWULN : 60-02-0F-20-00-00-43-D4-43-FD-DE-9C-00-0A-AE-1B ==== Target Persistent Binding Information ======= No target persistent data found on HBA 0. ==== Selective LUNs Information ================== ==== Boot Device Information ===================== ----------------------------------------------------------------------------- QLogic HBA 0 - QLA/QCP/QSB22xx OS: 0 WWPN: 21-00-00-E0-8B-05-67-B8 ----------------------------------------------------------------------------- Primary Boot Device Information: -------------------------------------- Selectable Boot: Disabled -------------------------------------- Device Node Name Device Port Name Device ID LUN ID ----------------------- ----------------------- --------- ------ 00-00-00-00-00-00-00-00 00-00-00-00-00-00-00-00 0 0 ==== Driver Settings Information ================= ----------------------------------------------------------------- QLogic HBA 0 - QLA/QCP/QSB22xx OS: 0 WWPN: 21-00-00-E0-8B-05-67-B8 ----------------------------------------------------------------- ----------------------------------- Driver Settings - Group: Persistent ----------------------------------- Present targets that are persistently bound plus any new target(s) : Enable Present targets that are persistently bound Only : Disable -------------------------------- Driver Settings - Group: Binding -------------------------------- Bind by World Wide Port Name: Enable Bind by Port ID : Disable Press <Enter> to continue: root bdelbono # format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248> /pci@1f,0/pci@1,1/scsi@2/sd@0,0 1. c0t1d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248> /pci@1f,0/pci@1,1/scsi@2/sd@1,0 2. c4t1d0 <SUN-T300-0118 cyl 34530 alt 2 hd 144 sec 128> T3-Blue /pci@1f,0/pci@1/pci@1/scsi@f/sd@1,0 Specify disk (enter its number): ^D root bdelbono # cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::dsk/c0t1d0 disk connected configured unknown c1 scsi-bus connected configured unknown c1::dsk/c1t2d0 CD-ROM connected configured unknown root bdelbono # prtdiag -v System Configuration: Sun Microsystems sun4u Netra t1 (UltraSPARC-IIi 360MHz) System clock frequency: 90 MHz Memory size: 320 Megabytes ----------------------------------------------------------------------------- ========================= CPUs ========================= Run Ecache CPU CPU Brd CPU Module MHz MB Impl. Mask --- --- ------- ----- ------ ------ ---- 0 0 0 360 1.0 12 9.1 ========================= IO Cards ========================= Bus# Freq Brd Type MHz Slot Name Model --- ---- ---- ---- -------------------------------- ---------------------- 0 PCI-1 33 1 ebus 0 PCI-1 33 1 network-SUNW,hme 0 PCI-1 33 2 scsi-glm Symbios,53C875 0 PCI-1 33 3 network-SUNW,hme 0 PCI-2 33 1 pci-pci1011,22 No failures found in System =========================== ========================= HW Revisions ========================= ASIC Revisions: --------------- Cheerio: ebus Rev 1 System PROM revisions: ---------------------- OBP 3.10.27 2000/06/22 16:45 POST 1.17.0 2000/03/06 12:18 root bdelbono # uname -a SunOS san 5.9 Generic_118558-22 sun4u sparc SUNW,UltraSPARC-IIi-cEngine --------------------------------------------------------------------------- Switch Information Report for san --------------------------------------------------------------------------- List of Switches Switch ID Worldwide Name Enet IP Addr FC IP Addr Name ------------------------------------------------------------------------- 1: fffc01 10:00:00:60:69:30:1a:b9 10.10.33.199 0.0.0.0 >"san" Ethernet IP Address: 10.10.33.199 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: none Fibre Channel Subnetmask: none Gateway Address: 10.10.33.1 Kernel: 5.4 Fabric OS: v2.6.2c Made on: Wed Jan 26 15:08:33 PST 2005 Flash: Wed Jan 26 15:09:13 PST 2005 BootProm: Wed Sep 22 13:48:55 PDT 1999 List of Inter-Switch Links Local Domain ID: 1 Local Port Domain Remote Port State ------------------------------------------------------- List of Ports switchName: san switchType: 4.1 switchState: Online switchMode: Native switchRole: Principal switchDomain: 1 switchId: fffc01 switchWwn: 10:00:00:60:69:30:1a:b9 switchBeacon: ON Zoning: ON (sancfg) port 0: sw Online L-Port 1 private, 2 phantom port 1: sw Online F-Port 21:00:00:e0:8b:05:67:b8 port 2: sw No_Light port 3: sw No_Light port 4: sw No_Light port 5: sw No_Light port 6: sw No_Light port 7: -- No_Module Name Server { 0100e8 010100 2 Nx_Ports in the Fabric } { Type Pid COS PortName NodeName TTL(sec) NL 0100e8; 3;50:02:0f:23:00:00:43:d4;50:02:0f:20:00:00:43:d4; na FC4s: FCP [SUN T300 0118] Fabric Port Name: 20:00:00:60:69:30:1a:b9 N 010100; 3;21:00:00:e0:8b:05:67:b8;20:00:00:e0:8b:05:67:b8; na FC4s: FCP Fabric Port Name: 20:01:00:60:69:30:1a:b9 The Local Name Server has 2 entries } Zoning Information Defined configuration: cfg: sancfg zone zone: zone alias alias: alias 50:02:0f:23:00:00:43:d4; 21:00:00:e0:8b:05:67:b8 Effective configuration: cfg: sancfg zone: zone Protocol:ALL 50:02:0f:23:00:00:43:d4 21:00:00:e0:8b:05:67:b8 GBIC Serial ID Information port 0: sw port 1: sw port 2: sw port 3: sw port 4: sw port 5: sw port 6: sw port 7: -- --------------------------------------------------------------------------- 2) A second solution is to use a FC-AL Hub instead of a switch. This should get around the problem as it would do L_port rather than a Fabric port/mode. Thanks again everyone. Warm Regards, -- Bruno Delbono Open-Systems Group http://www.open-systems.org/users/bruno/ Bruno S. Delbono wrote: > Hi Gurus, > > I need some help and promise that I'll summarize. I recently acquired > two used Storedge T3 (9 x 36 GB FC-AL), a Netra T1 with a QLogic (ifp0) > SAN HBA card and a Compaq/HP 1 GB/s 8-EL Switch [*]. I am running > Solaris 9 on the server and have installed SAN 4.4.8 for Solaris 9. > > I've created a raid 0 volume on the T3 and if I connect the T3 directly > to the Netra's SAN HBA card...I can see my new volume/disk. So...this > works (using FC-AL loop). > > BUT, if I connect the T3 and the netra to the Fiber Switch, Solaris > cannot see the disk. Here's what I get in /var/adm/messages (tons of > these). > > Feb 23 18:32:46 san scsi: [ID 243001 kern.info] > /pci@1f,0/pci@1/pci@1/SUNW,ifp@f (ifp0): > Feb 23 18:32:46 san Loop reconfigure in progress > Feb 23 18:32:46 san scsi: [ID 243001 kern.warning] WARNING: > /pci@1f,0/pci@1/pci@1/SUNW,ifp@f (ifp0): > Feb 23 18:32:46 san mbox cmd failed for alpa: 0xef, rval: 0x4006 > Feb 23 18:32:46 san scsi: [ID 243001 kern.info] > /pci@1f,0/pci@1/pci@1/SUNW,ifp@f (ifp0): > Feb 23 18:32:46 san Unable to allocate target structure for switch > setting 0 > Feb 23 18:32:46 san reason: Unable to get port database > > Here's the uname -a: > > SunOS san 5.9 Generic_117171-07 sun4u sparc SUNW,UltraSPARC-IIi-cEngine > > The switch can see both the Netra's SAN card "and" the T3. I've created > the a zone with both their WWN's but for some reason I keep getting > these errors and am unable to see the disk. > > PS - This is a Fabric Switch. Do I need cfgadm -al to configure it (if I > can around this problem)? Or do I need luxadm insert? > > I've spent a lot of time going over reports on sunsolve, hp.com's > support but I have come up with zilch. I don't understand why this works > directly but fails to work. Here's a screenshot in case it helps. > > http://www.open-systems.org/users/bruno/SANerror.JPG > > I would sincerely appreciate any help. Better yet, IOU a beer if you can > help me figure this out. > > [*] - > http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp?&lang=en&cc=us&prodTypeId=12169&prodSeriesId=311232&lang=en&cc=us > > Thanks again > > Warm Regards, > > -- > Bruno Delbono > Open-Systems Group > http://www.open-systems.org/users/bruno/ > _______________________________________________ > sunmanagers mailing list > sunmanagers@sunmanagers.org > http://www.sunmanagers.org/mailman/listinfo/sunmanagers _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Wed Mar 1 20:38:45 2006
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:56 EST