SUMMARY: Disksuite error on bootup what's it mean?

From: Dave Martini <martini_at_mrpeabody.llnl.gov>
Date: Wed May 03 2006 - 12:30:18 EDT
Thanks everyone the people on this list are amazing!

I had put my own inetd.conf file in place so didn't have these lines in 
there.
I added them and no more error on bootup.
Do I need all 3 of thse entries? Not sure what they do exactly.

# METAD - SLVM metadb Daemon
100229/1        tli     rpc/tcp wait    root    /usr/sbin/rpc.metad 
rpc.metad
# METAMHD - SLVM HA Daemon
100230/1        tli     rpc/tcp wait    root    /usr/sbin/rpc.metamhd 
rpc.metamhd
# METAMEDD - SLVM Mediator Daemon
100242/1        tli     rpc/tcp wait    root    /usr/sbin/rpc.metamedd 
rpc.metamedd


Thank You.
Dave.

Below is my original question

I'm using Sun Storedge Manager (Disksuite) on solaris 9.

When the machine boots up each time I get a message on the screen that says

metaset: hostname metad client create RPC program not regsitered.

What does this mean?

I'm only using disksuite to mirror the boot disk.

I have a 3320 array connected to this machine and I have Veritas Volume
Manager installed which I'm using to strip/mirror the disks in the array.

Is the message above related to the 3320?
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Wed May 3 12:31:04 2006

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:57 EST