[SUMMARY] FC controllers and disks issues after installation of Sun StorEdge 3510 FC

From: Vladimir Terziev <vlady_at_gbservices.biz>
Date: Thu Aug 10 2006 - 12:27:53 EDT
	If you want to see the right condition of the FC controllers and disks, issue the `cfgadm -al' command as root !!!

		Vladimir


On Thu, 10 Aug 2006 19:06:52 +0300
Vladimir Terziev <vlady@gbservices.biz> wrote:

> 	Hi Managers,
> 
> 	i have Sun StorEdge 3510 (SE 3510) disk array which i have connected to a Sun V880 server.
> 
> 	The V880 has 3 FC disk controllers -- one managing the internal disks and 2 managing two different external storage arrays - one T3B array and the recently installed SE 3510 array.
> 
> 	After power-up of the 3510 array i saw very stange information regarding FC controllers and disks. `cfgadm -al' shows all FC controllers in condition "failed" and all disks connected to the controllers in condition "failing".
> 	Despite this, it seems the V880 machine continue to work properly.
> 
> 	Could someone point me to some explanation/solution regarding the problem ?
> 
> 	Do i have to issue `cfgadm -t' or reconfiguration reboot in order to move the disks and controllers in "ok" condition ?
> 
> 	Thanks in advance!
> 
> 		Vladimir
> _______________________________________________
> sunmanagers mailing list
> sunmanagers@sunmanagers.org
> http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Thu Aug 10 12:28:34 2006

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:44:00 EST