SUMMARY: Mpxio and Internal Fiber Drives

From: <michael_warnock_at_vanguard.com>
Date: Mon Oct 16 2006 - 10:01:13 EDT
Thank you for all the responses.

The solution was to edit /kernel/drv/qlc.conf as follows:

You need to edit /kernel/drv/qlc.conf and put in

name="qlc" parent="/pci@9,600000" unit-address="2" mpxio-disable="yes"

=====================================
ORIGINAL POST

SunFire V490
Solaris 8
Sun Qlogic cards / Mpxio
SVM Boot disk
VxVM 4.1 Application data

Recently we have been migrating to Qlogic and Mpxio ( away from
Emulex/Powerpath ).
On the server above we had 4 internal drives

      0. c0t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@8,700000/pci@2/scsi@2/sd@0,0
       1. c0t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@8,700000/pci@2/scsi@2/sd@1,0

       2. c2t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000014c36bcc53,0
       3. c2t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000014c36bcfdb,0


Now,  after installing Mpxio and the Qlogic cards
Mpxio has taken "control" of c2.

This is not what I want
I only want Mpxio to manage my EMC data ( which are c6 and c7 -- virtual c8
)

c6                             fc-fabric    connected    configured
unknown
c6::50060482c4654e43           disk         connected    configured
unknown
c7                             fc-fabric    connected    configured
unknown
c7::50060482c4654e4c           disk         connected    configured
unknown


       0. c0t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@8,700000/pci@2/scsi@2/sd@0,0
       1. c0t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@8,700000/pci@2/scsi@2/sd@1,0

       2. c8t20000014C36BCC53d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /scsi_vhci/ssd@g20000014c36bcc53
       3. c8t20000014C36BCFDBd0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /scsi_vhci/ssd@g20000014c36bcfdb

       4. c8t6006048000018570168956434D303032d0 <EMC-SYMMETRIX-5568 cyl 14
alt 2 hd 15 sec 64>
          /scsi_vhci/ssd@g6006048000018570168956434d303032


How do I "tell" mpxio to NOT manage c2?


Michael Warnock
UTS/x38031


----------------------------------------------------------------------
CONFIDENTIALITY STATEMENT. The information contained in this e-mail message, including attachments, is the confidential information of, and/or is the property of, Vanguard. The information is intended for use solely by the individual or entity named in the message. If you are not an intended recipient or you received this in error, then any review, printing, copying, or distribution of any such information is prohibited, and please notify the sender immediately by reply e-mail and then delete this e-mail from your system.
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Mon Oct 16 10:01:46 2006

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:44:02 EST