partial SUMMARY: SunStorage 3310 (SCSI) EMU problem

From: Grzegorz Bakalarski <G.Bakalarski_at_icm.edu.pl>
Date: Wed Dec 13 2006 - 07:05:45 EST
On Wed, Dec 13, 2006 at 10:23:39AM +0100, Grzegorz Bakalarski wrote:
> sccli> show enclosure-status
> Ch  Id  Chassis  Vendor  Product ID        Rev   Package   Status
> -----------------------------------------------------------------
>  0  14  005C0A   SUN     StorEdge 3310  A  A000  A000      Fault
> 
> Enclosure Component Status:
>      Type Unit Status   FRU P/N   FRU S/N   Add'l Data
> ------------------------------------------------------------------
>       Fan 0    OK       370-5398  108198     --
>       Fan 1    OK       370-5398  108228     --
>        PS 0    OK       370-5398  108198     --
>        PS 1    OK       370-5398  108228     --
>      Temp 0    OK       370-5524  005C0A     temp=22
>      Temp 1    OK       370-5524  005C0A     temp=22
>      Temp 2    OK       370-5398  108198     temp=22
>      Temp 3    OK       370-5394  026348     temp=30
>      Temp 4    OK       370-5394  026023     temp=23
>      Temp 5    OK       370-5524  005C0A     temp=22
>      Temp 6    OK       370-5398  108228     temp=23
>       EMU 0    Unknown  370-5394  026348     
>       EMU 1    Unknown  370-5394  026023     
>  DiskSlot 0    Absent   370-5524  005C0A     addr=0,led=off
>  DiskSlot 1    Absent   370-5524  005C0A     addr=1,led=off
>  DiskSlot 2    Absent   370-5524  005C0A     addr=2,led=off
>  DiskSlot 3    Absent   370-5524  005C0A     addr=3,led=off
>  DiskSlot 4    Absent   370-5524  005C0A     addr=4,led=off
>  DiskSlot 5    Absent   370-5524  005C0A     addr=5,led=off
>  DiskSlot 6    OK       370-5524  005C0A     addr=0,led=off
>  DiskSlot 7    OK       370-5524  005C0A     addr=1,led=off
>  DiskSlot 8    OK       370-5524  005C0A     addr=2,led=off
>  DiskSlot 9    OK       370-5524  005C0A     addr=3,led=off
>  DiskSlot 10   OK       370-5524  005C0A     addr=4,led=off
>  DiskSlot 11   OK       370-5524  005C0A     addr=5,led=off
> 
> 
> Enclosure SCSI Channel Type: single-bus
> sccli>
> 

Hi,

Nobody responded yet. However I have some better result now.
I'v upgreaded saf-te firmware from factory default (A00000)
to rev 1170 (patch 113722-09) and now I get the following:

sccli> show enclosure-status
Ch  Id  Chassis  Vendor  Product ID        Rev   Package   Status
-----------------------------------------------------------------
 0  14  005C0A   SUN     StorEdge 3310  A  1170  1170         OK

Enclosure Component Status:
     Type Unit Status   FRU P/N   FRU S/N   Add'l Data
------------------------------------------------------------------
      Fan 0    OK       370-5398  108198     --
      Fan 1    OK       370-5398  108228     --
       PS 0    OK       370-5398  108198     --
       PS 1    OK       370-5398  108228     --
     Temp 0    OK       370-5524  005C0A     temp=21
     Temp 1    OK       370-5524  005C0A     temp=21
     Temp 2    OK       370-5398  108198     temp=22
     Temp 3    OK       370-5394  026348     temp=27
     Temp 4    OK       370-5394  026023     temp=22
     Temp 5    OK       370-5524  005C0A     temp=22
     Temp 6    OK       370-5398  108228     temp=23
      EMU 0    OK       370-5394  026348     
      EMU 1    OK       370-5394  026023     
 DiskSlot 0    Unknown  370-5524  005C0A     addr=0,led=off
 DiskSlot 1    Unknown  370-5524  005C0A     addr=1,led=off
 DiskSlot 2    Unknown  370-5524  005C0A     addr=2,led=off
 DiskSlot 3    Unknown  370-5524  005C0A     addr=3,led=off
 DiskSlot 4    Unknown  370-5524  005C0A     addr=4,led=off
 DiskSlot 5    Unknown  370-5524  005C0A     addr=5,led=off
 DiskSlot 6    OK       370-5524  005C0A     addr=0,led=off
 DiskSlot 7    OK       370-5524  005C0A     addr=1,led=off
 DiskSlot 8    OK       370-5524  005C0A     addr=2,led=off
 DiskSlot 9    OK       370-5524  005C0A     addr=3,led=off
 DiskSlot 10   OK       370-5524  005C0A     addr=4,led=off
 DiskSlot 11   OK       370-5524  005C0A     addr=5,led=off

Enclosure SCSI Channel Type: split-bus
sccli> 


Note: EMU 0 and EMU 1 have OK status.
And also SCSI Channel Type is correct i.e.
split-bus.

The only concern is now why disks in slots [0-5]
are Unknown ????

Kind regards,

Gb
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Wed Dec 13 07:07:20 2006

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:44:03 EST