SUMMARY: RAID 10 (1+0) with Solstice Disksuite

From: Michael Hale <mhale_at_transcomus.com>
Date: Tue Jan 30 2007 - 14:28:36 EST
Thanks to Jeff Horwitz, Matthew Stier, Darren Dunham, and KR  
(rossman@columbia.edu)

Turns out that SDS/SVM optimizes new RAID 0+1 volumes into RAID 1+0  
just as long as the number of columns in each of the mirrored strips  
is the same and the sized of the physical disk slices in each column  
is the same, even though there is no difference in it's outward  
appearance.

Also, Matthew Stier provided this link, which verifies that this is  
indeed the case:

http://chrismiles.info/unix/sun/dsraid10.txt
--
Michael Hale
mhale@transcomus.com
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Tue Jan 30 14:29:21 2007