SUMMARY meta database - disk failing

From: Beverley Reynolds <breynolds_at_Cymtec.com>
Date: Thu Jun 04 2009 - 14:05:10 EDT
Thanks to all who replied.

I opened a case with SUN and originally they said the disk needed
replacing but after a week of emails it turns out that all that needed
to be done was to delete the meta database on c0t2d0s7 and recreate them
which I did.  Now metadb shows



metadb

        flags           first blk       block count

     a m  p  luo        16              8192
/dev/dsk/c0t0d0s7

     a        u         16              8192
/dev/dsk/c0t1d0s7

     a        u         8208            8192
/dev/dsk/c0t1d0s7

     a        u         16400           8192
/dev/dsk/c0t1d0s7

     a    p  luo        8208            8192
/dev/dsk/c0t0d0s7

     a    p  luo        16400           8192
/dev/dsk/c0t0d0s7



Which has the meta database on c0t2d0s7 as updated - not sure why the
"l" and "o" flags are not showing up. But the write error is gone.



Bev





I have a disk going out on my SUN T2000.

There are two internal disks - one a mirror.

The disk that is going bad has the master mirror database on it.



Can you tell me the procedures for breaking the mirror and replacing the

disk without losing the data on it?







metadb



        flags           first blk       block count



     a m  p  luo        16              8192 /dev/dsk/c0t0d0s7

      W   p  l          16              8192 /dev/dsk/c0t1d0s7

      W   p  l          8208            8192 /dev/dsk/c0t1d0s7

     a    p  luo        16400           8192 /dev/dsk/c0t1d0s7

     a    p  luo        8208            8192 /dev/dsk/c0t0d0s7

     a    p  luo        16400           8192 /dev/dsk/c0t0d0s7







Thanks






#############################################################################
##
This message from Cymtec Systems, Inc. contains confidential information and
is solely for the use of the recipient(s) named above.  If you are not the
intended recipient or an agent responsible for delivering it to the intended
recipient, you are hereby notified that you have received this message in
error and that any review, disclosure, copying, distribution or use of the
contents of this message is strictly prohibited.  If you have received this
message in error, please destroy it immediately and notify Cymtec Systems,
Inc. by telephone at +1.314.993.8700 or by return e-mail.
#############################################################################
##
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Thu Jun 4 14:07:56 2009

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:44:14 EST