Re: SUMMARY: how to force output?

From: sunhux G <sunhux_at_gmail.com>
Date: Thu Sep 03 2009 - 06:12:27 EDT
Hi


Sorry didn't summarize earlier as not  certain what's the cause earlier.

Since Tomek & me are applying different firmwares
(139436-03 & 127580-05 respectively), I guess Tomek
probably has spotted that the power cycling and reflashing
resolved this problem of "prtdiag -v" gave "segmentation fault"


Rgds
U

===========================================================

Hi,

I've manage to fix this. Ive flashed the firmware once again and it worked
:)
after Flashing Ive powered down the machine totally, even plugged off the
power cords.
It helped for me.

Regards
Tomek
 Tomasz Ostrowski

 ------------------------------
*From:* ext sunhux G [mailto:sunhux@gmail.com]
*Sent:* Thursday, September 03, 2009 11:37 AM
*To:* Ostrowski, Tomasz (NSN - CN/Shanghai)
*Subject:* Re: "prtdiag -v" segmentation fault after firmware patch
127580-05

Sorry for the late reply.

My "segmentation fault" is gone after my colleague applied the latest
full Solaris 10 patches, power cycled & it just went away.



Regds
U

On Wed, Sep 2, 2009 at 2:56 AM, Ostrowski, Tomasz (NSN - CN/Shanghai) <
tomasz.ostrowski@nsn.com> wrote:

Hello,

Did you manage to solve your issue?
*http://www.sunmanagers.org/pipermail/sunmanagers/2008-April/045587.html*<http://www.sunmanagers.org/pipermail/sunmanagers/2008-April/045587.html>

I have T2000 and I have just upgradet the firmware: 139436-03

And now I have this
root@comm1> prtdiag -v
System Configuration:  Sun Microsystems  sun4v Netra T2000
Memory size: 16256 Megabytes

================================ Virtual CPUs
================================

CPU ID Frequency Implementation         Status
------ --------- ---------------------- -------

======================= Physical Memory Configuration
========================
Segment Table:
--------------------------------------------------------------
Base           Segment  Interleave  Bank     Contains
Address        Size     Factor      Size     Modules
--------------------------------------------------------------
0x0            16 GB    4           2 GB     MB/CMP0/CH0/R0/D0
                                             MB/CMP0/CH0/R0/D1
                                    2 GB     MB/CMP0/CH0/R1/D0
                                             MB/CMP0/CH0/R1/D1
                                    2 GB     MB/CMP0/CH1/R0/D0
                                             MB/CMP0/CH1/R0/D1
                                    2 GB     MB/CMP0/CH1/R1/D0
                                             MB/CMP0/CH1/R1/D1
                                    2 GB     MB/CMP0/CH2/R0/D0
                                             MB/CMP0/CH2/R0/D1
                                    2 GB     MB/CMP0/CH2/R1/D0
                                             MB/CMP0/CH2/R1/D1
                                    2 GB     MB/CMP0/CH3/R0/D0
                                             MB/CMP0/CH3/R0/D1
                                    2 GB     MB/CMP0/CH3/R1/D0
                                             MB/CMP0/CH3/R1/D1

========================= IO Configuration =========================

            IO
Location    Type  Slot Path
Name                      Model
----------- ----- ---- ---------------------------------------------
------------------------- ---------
IOBD/NET0    PCIE IOBD                /pci@780/pci@0/pci@1/network@0
network-pciex8086,105e
IOBD/NET1    PCIE IOBD              /pci@780/pci@0/pci@1/network@0,1
network-pciex8086,105e
IOBD/PCIE    PCIE IOBD                   /pci@780/pci@0/pci@9/scsi@0
scsi-pciex1000,56
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/isa@2
isa
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@5
usb-pciclass,0c0310
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@6
usb-pciclass,0c0310
IOBD/NET2    PCIE IOBD                /pci@7c0/pci@0/pci@2/network@0
network-pciex8086,105e
IOBD/NET3    PCIE IOBD              /pci@7c0/pci@0/pci@2/network@0,1
network-pciex8086,105e

========================= HW Revisions
=======================================

System PROM revisions:
----------------------
OBP 4.30.3 2009/06/08 13:29

IO ASIC revisions:
------------------
Location             Path
Device                         Revision
-------------------- ---------------------------------------------
------------------------------ ---------
Segmentation Fault (core dumped)



But without -v is ok

root@comm1> prtdiag
System Configuration:  Sun Microsystems  sun4v Netra T2000
Memory size: 16256 Megabytes

================================ Virtual CPUs
================================

CPU ID Frequency Implementation         Status
------ --------- ---------------------- -------

======================= Physical Memory Configuration
========================
Segment Table:
--------------------------------------------------------------
Base           Segment  Interleave  Bank     Contains
Address        Size     Factor      Size     Modules
--------------------------------------------------------------
0x0            16 GB    4           2 GB     MB/CMP0/CH0/R0/D0
                                             MB/CMP0/CH0/R0/D1
                                    2 GB     MB/CMP0/CH0/R1/D0
                                             MB/CMP0/CH0/R1/D1
                                    2 GB     MB/CMP0/CH1/R0/D0
                                             MB/CMP0/CH1/R0/D1
                                    2 GB     MB/CMP0/CH1/R1/D0
                                             MB/CMP0/CH1/R1/D1
                                    2 GB     MB/CMP0/CH2/R0/D0
                                             MB/CMP0/CH2/R0/D1
                                    2 GB     MB/CMP0/CH2/R1/D0
                                             MB/CMP0/CH2/R1/D1
                                    2 GB     MB/CMP0/CH3/R0/D0
                                             MB/CMP0/CH3/R0/D1
                                    2 GB     MB/CMP0/CH3/R1/D0
                                             MB/CMP0/CH3/R1/D1

========================= IO Configuration =========================

            IO
Location    Type  Slot Path
Name                      Model
----------- ----- ---- ---------------------------------------------
------------------------- ---------
IOBD/NET0    PCIE IOBD                /pci@780/pci@0/pci@1/network@0
network-pciex8086,105e
IOBD/NET1    PCIE IOBD              /pci@780/pci@0/pci@1/network@0,1
network-pciex8086,105e
IOBD/PCIE    PCIE IOBD                   /pci@780/pci@0/pci@9/scsi@0
scsi-pciex1000,56
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/isa@2
isa
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@5
usb-pciclass,0c0310
IOBD/PCIX    PCIX IOBD              /pci@7c0/pci@0/pci@1/pci@0/usb@6
usb-pciclass,0c0310
IOBD/NET2    PCIE IOBD                /pci@7c0/pci@0/pci@2/network@0
network-pciex8086,105e
IOBD/NET3    PCIE IOBD              /pci@7c0/pci@0/pci@2/network@0,1
network-pciex8086,105e

============================ Environmental Status
============================
Fan sensors:
All fan sensors are OK.

Temperature sensors:
All temperature sensors are OK.

Current sensors:
All current sensors are OK.

Current indicators:
All current indicators are OK.

Voltage sensors:
All voltage sensors are OK.

============================ FRU Status ============================
All FRUs are enabled.

Any help is more that welcome :)

Best Regards
Tomek

=====================================================================

Apr 2008

Hi Sunmanagers,


I've just applied patch 127580-05 on our T5120
running Solaris 10.

Rebooted the system & this time,  "prtdiag -v"
would give segmentation fault half through the
output.

U
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Fri Sep 4 14:15:09 2009