Sun Admins: I got it working with several useful suggestions from the group members. Thanks a billion for that. Here is what I had to do: # powermt display dev=all Pseudo name=emcpower2a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170022F679145BADE011 [LUN 36] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016141E01079d0s0 SP A1 active alive 0 0 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016941E01079d0s0 SP B1 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016041E01079d0s0 SP A0 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016841E01079d0s0 SP B0 active alive 0 0 Pseudo name=emcpower0a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170023F679145BADE011 [LUN 37] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3073 UNKNOWN unknown SP A0 active alive 0 0 3074 UNKNOWN unknown SP B1 active alive 0 0 3073 UNKNOWN unknown SP B0 active alive 0 0 3074 UNKNOWN unknown SP A1 active alive 0 0 Pseudo name=emcpower1a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170024F679145BADE011 [LUN 38] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3073 UNKNOWN unknown SP A0 active alive 0 0 3074 UNKNOWN unknown SP B1 active alive 0 0 3074 UNKNOWN unknown SP A1 active alive 0 0 3073 UNKNOWN unknown SP B0 active alive 0 0 # # cd /etc # mv powermt.custom powermt.custom.0rig # cd /kernel/drv # mv emcp.conf emcp.conf.0rig # devfsadm -C # powermt config # powercf -q [To rebuild Powerpath logical links] # powermt display dev=all Pseudo name=emcpower2a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170022F679145BADE011 [LUN 36] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016141E01079d0s0 SP A1 active alive 0 0 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016941E01079d0s0 SP B1 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016041E01079d0s0 SP A0 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016841E01079d0s0 SP B0 active alive 0 0 Pseudo name=emcpower0a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170023F679145BADE011 [LUN 37] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016141E01079d2s0 SP A1 active alive 0 0 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016941E01079d2s0 SP B1 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016041E01079d2s0 SP A0 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016841E01079d2s0 SP B0 active alive 0 0 Pseudo name=emcpower1a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170024F679145BADE011 [LUN 38] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016141E01079d1s0 SP A1 active alive 0 0 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016941E01079d1s0 SP B1 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016041E01079d1s0 SP A0 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016841E01079d1s0 SP B0 active alive 0 0 # powermt save # Kennedy G. Doss (C K-Force, Consultant for: Regional Service Delivery Americas)&Application Hosting Services GIS (C Global Infrastructure Services TEL: 908 (C 981 (C 5295 )&CELL: 732 (C 371 (C 2887 55 Corporate Drive (C Bridgewater (C New Jersey [cid:image001.jpg@01CC453C.8B3878B0] (9 Please consider the environment before printing this email From: Doss, Kennedy G. PH/US/EXT Sent: Monday, July 18, 2011 8:33 AM To: sunmanagers@sunmanagers.org Subject: Recognizing EMC Clariion LUNs on a SOLARIS 10 Server Importance: High Sun Admins: This my first experience with configuring Solaris 10 with CLARiiON disks. I have presented 3 disks from the CLARiiON Array to the Sun Solaris Host. I have loaded EMC's PowerPath. I tried to run a "powermt display" and only 1 out of the 3 disks show valid paths - though all the three disks are marked active. Is there something that I am missing on the server side? Any help from your end would be most appreciated. # powermt display dev=all Pseudo name=emcpower2a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170022F679145BADE011 [LUN 36] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016141E01079d0s0 SP A1 active alive 0 0 3074 pci@1e,600000/SUNW,emlxs@2/fp@0,0 c2t5006016941E01079d0s0 SP B1 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016041E01079d0s0 SP A0 active alive 0 0 3073 pci@1e,600000/SUNW,emlxs@2,1/fp@0,0 c3t5006016841E01079d0s0 SP B0 active alive 0 0 Pseudo name=emcpower0a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170023F679145BADE011 [LUN 37] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3073 UNKNOWN unknown SP A0 active alive 0 0 3074 UNKNOWN unknown SP B1 active alive 0 0 3073 UNKNOWN unknown SP B0 active alive 0 0 3074 UNKNOWN unknown SP A1 active alive 0 0 Pseudo name=emcpower1a CLARiiON ID=APM00063105053 [SOLARIS10_SLC_TESTING] Logical device ID=600601601B50170024F679145BADE011 [LUN 38] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3073 UNKNOWN unknown SP A0 active alive 0 0 3074 UNKNOWN unknown SP B1 active alive 0 0 3074 UNKNOWN unknown SP A1 active alive 0 0 3073 UNKNOWN unknown SP B0 active alive 0 0 # Kennedy G. Doss (C K-Force, Consultant for: Regional Service Delivery Americas)&Application Hosting Services GIS (C Global Infrastructure Services TEL: 908 (C 981 (C 5295 )&CELL: 732 (C 371 (C 2887 55 Corporate Drive (C Bridgewater (C New Jersey [cid:image001.jpg@01CC453C.8B3878B0] (9 Please consider the environment before printing this email [demime 1.01b removed an attachment of type image/jpeg which had a name of image001.jpg] _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Mon Jul 18 11:19:43 2011
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:44:18 EST