> We have a sun4/470 running 4.1.1 which has one IPI
> controller (idc0) on which sits 4 disks: CDC IPI 9720
>
> 5 times now, the label for disk id000 has found its way
> to the disk id001 with of course very bad side effects for
> anything using id001.
As I'm not the manager of the machine in question, I was missing
some information. Thanks to all the people who answered, most of
whom diagnosed the problem correctly as a use of dd to copy
the first partition of disk 0 to the first partition of disk 1.
The label is in the first block and gets copied along, the next
time the system boots, the disk 1 doesn't mount properly anymore
since they don't have the same partition tables.
clive@jtsv16.jts.com (Clive Beddall ) also had this to say:
> I had a problem with the same equipment, only the drive id002
> would lose a label...we were having problems due to our partitions.
> Both drive 1 and 2 were partitioned and used only as "C" one
> partition. We have now changed to one large "B" partition
> the same size as "C" and all is well.
Thanks to:
tim@ben.dciem.dnd.ca (Tim Pointing)
stpeters@dawn.crd.ge.com (Dick St.Peters)
dal@gcm.com (Dan Lorenzini)
dan@breeze.bellcore.com (Daniel Strick)
per@erix.ericsson.se (Per Hedeland)
keane@socs.uts.EDU.AU Chris Keane
John DiMarco <jdd@db.toronto.edu>
Alain Brossard, Ecole Polytechnique Federale de Lausanne,
SIC/SII, EL-Ecublens, CH-1015 Lausanne, Suisse, +41 21 693-2211
brossard@sic.epfl.ch