Summary: sd3c: Sense Key Hardware Error

From: Sue Chichester (SUE@uno.cc.geneseo.edu)
Date: Tue May 04 1993 - 13:30:49 CDT


Original note:

>I have begun to get the following
>
>
>May 3 08:45:04 ram vmunix: sd3c: Error for command 'write'
>May 3 08:45:04 ram vmunix: sd3c: Error Level: Fatal
>May 3 08:45:04 ram vmunix: sd3c: Block 1849168 Absolute Block = 1849170
>May 3 08:45:04 ram vmunix: sd3c: Sense Key: Hardware Error
>May 3 08:45:04 ram vmunix: sd3c: Vendor 'IMPRIMIS' error code: 0x3

Things degraded rather quickly to an unuseable system. I reformated the
drive and reloaded from backup tape. It's working fine for now.

Sue Chichester
SUNY Geneseo
sue@geneseo.bitnet
sue@uno.cc.geneseo.edu



This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:07:48 CDT