Hi administrators
Thanks for your help. Wow, I got the helping answer in a couple of
minutes!!!!
Many thanks to Stefan Voss at TerraData Germany (s.voss@terradata.de).
The frequences of a framebuffer can be set via the ok-prompt.
Example: setenv output-device screen:r1152x900x66
There was allready an SUMMARY last year for the same problem!!!
This are all possible resolutions/frequencies :
Resolution ZX GT GS GX GX+ TGX TGX+ CG14 A24
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1600x1280@66 | | | | | | | yes | yes | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1280x1024@76 | yes | yes | | | | | yes | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1280x1024@67 | yes | yes | | | yes | | yes | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1280x1024@66 | | | | | | | | yes | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1152x900@76 | yes | | yes | yes | yes | yes | yes | yes | yes |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1152x900@66 | yes | | | yes | yes | yes | yes | yes | yes |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1024x800@84 | | | | | | | | yes | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1024x768@77 | | | | | | yes | yes | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1024x768@76 | yes | | | | | | | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1024x768@70 | | | | | | | | yes | yes |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1024x768@66 | | | | | | | | yes | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
1024x768@60 | yes | | | | | yes | yes | yes | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
Stereo
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
960x680@108 | yes | | | | | | | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
960x680@112 | yes | | | | | | | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
960x680@120 | | yes | | | | | | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
PAL
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
770x575@50 | yes | | | | | | | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
NTSC
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
640x480@59.94 | yes | yes | | | | | | | |
---------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
A Note about the 13W3 connector and Sun Framebuffers
----------------------------------------------------
Besides the red, green, blue and sync connections, the Sun monitor
connector (called 13W3) has several sense pins which allow the
monitor to tell the framebuffer what resolutions and frequencies
it can handle. The sense pins are pins 3 (S2), 8 (S1) and 9 (S0).
These are used in combination with pin 4 (GND) to communicate the
resolutions to the framebuffer. The table below is a list of how
the pins are interpreted. Many of the framebuffers will not allow
user to put them in a mode that the monitor says it does not
support. If trying to put the framebuffer in a particular
resolution but it won't go, check to see if the monitor supports
the resolution.
Scan Rate Code S2 S1 S0
---------------+-----+-----+-----+-----+
1152x900 66hz | 7 | | | |
---------------+-----+-----+-----+-----+
1152x900 76hz | 6 | | | GND |
---------------+-----+-----+-----+-----+
1024x768 60hz | 5 | | GND | |
---------------+-----+-----+-----+-----+
1152x900 76hz | 4 | | GND | GND |
---------------+-----+-----+-----+-----+
1152x900 66hz | 3 | GND | | |
---------------+-----+-----+-----+-----+
1280x1024 76hz | 2 | GND | | GND |
---------------+-----+-----+-----+-----+
1600x1280 76hz | 1 | GND | GND | |
---------------+-----+-----+-----+-----+
1024x768 77hz | 0 | GND | GND | GND |
---------------+-----+-----+-----+-----+
Regards,
Peter
-- ======== Peter Dobler, Hirschgaesslein 38, CH-4051 Basel IT VISION AG Tel 061 206 96 05 Fax 061 206 96 10 ======== Email peter.dobler@ch.it-vision.com
This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:12:41 CDT